{
  "category": "Commercial Dishwashers",
  "vertical": "foodservice-equipment-and-supply",
  "source": "https://getclaro.ai/resources/attribute-library/foodservice-equipment-and-supply/commercial-dishwashers/",
  "status": "editorial-draft",
  "note": "Editorial reference template. Example values show format only and do not describe a real SKU. Not an official ETIM or ECLASS class.",
  "groups": [
    {
      "key": "identity",
      "name": "Identity",
      "check": "Preserve leading zeros and punctuation, validate against the manufacturer record, and check the GTIN check digit and packaging level before linking."
    },
    {
      "key": "technical",
      "name": "Technical specifications",
      "check": "Store the number and unit separately. Convert only when the source unit and test conditions are known."
    },
    {
      "key": "selection",
      "name": "Selection attributes",
      "check": "Map supplier wording to a governed vocabulary only after checking the source text and which variant it applies to."
    },
    {
      "key": "fit",
      "name": "Fit & compatibility",
      "check": "Keep model and series qualifiers. A similar-looking part is not a verified fit until a source says so."
    },
    {
      "key": "evidence",
      "name": "Evidence & compliance",
      "check": "Link the manufacturer document or label with its edition or date. Never copy a certification from a neighboring SKU."
    }
  ],
  "fields": [
    {
      "key": "machine_type",
      "label": "Machine Type",
      "group": "selection",
      "priority": "core",
      "value_type": "controlled",
      "unit": null,
      "example_format": "Single-tank door type"
    },
    {
      "key": "sanitizing_method",
      "label": "Sanitizing Method",
      "group": "selection",
      "priority": "core",
      "value_type": "controlled",
      "unit": null,
      "example_format": "High temperature (hot water sanitizing)"
    },
    {
      "key": "capacity_racks_per_hour",
      "label": "Capacity, Racks Per Hour",
      "group": "technical",
      "priority": "core",
      "value_type": "number",
      "unit": "racks/h",
      "example_format": "55"
    },
    {
      "key": "rack_size_accepted",
      "label": "Rack Size Accepted",
      "group": "fit",
      "priority": "core",
      "value_type": "controlled",
      "unit": null,
      "example_format": "19-3/4 x 19-3/4 in (standard 20 x 20 in rack)"
    },
    {
      "key": "electrical_supply_voltage_hz_phase",
      "label": "Electrical Supply (Voltage / Hz / Phase)",
      "group": "technical",
      "priority": "core",
      "value_type": "controlled",
      "unit": null,
      "example_format": "208-240 V / 60 Hz / 3 Ph"
    },
    {
      "key": "total_connected_load",
      "label": "Total Connected Load",
      "group": "technical",
      "priority": "core",
      "value_type": "number",
      "unit": "kW",
      "example_format": "17.2"
    },
    {
      "key": "final_rinse_water_consumption",
      "label": "Final Rinse Water Consumption",
      "group": "technical",
      "priority": "core",
      "value_type": "number",
      "unit": "gal/rack",
      "example_format": "0.74"
    },
    {
      "key": "incoming_water_supply_requirement",
      "label": "Incoming Water Supply Requirement",
      "group": "technical",
      "priority": "core",
      "value_type": "text",
      "unit": null,
      "example_format": "140 °F min supply; 20 ± 5 psi flowing; 4 gr/gal max hardness"
    },
    {
      "key": "overall_dimensions_w_x_d_x_h",
      "label": "Overall Dimensions (W x D x H)",
      "group": "technical",
      "priority": "core",
      "value_type": "text",
      "unit": "in",
      "example_format": "25-1/4 x 29-1/2 x 66-3/4 in (door closed)"
    },
    {
      "key": "manufacturer_part_number_mpn",
      "label": "Manufacturer Part Number (MPN)",
      "group": "identity",
      "priority": "core",
      "value_type": "identifier",
      "unit": null,
      "example_format": "DT-60HT-3P"
    },
    {
      "key": "gtin_14_upc_a",
      "label": "GTIN-14 / UPC-A",
      "group": "identity",
      "priority": "core",
      "value_type": "identifier",
      "unit": null,
      "example_format": "10012345600309"
    },
    {
      "key": "country_of_origin",
      "label": "Country of Origin",
      "group": "evidence",
      "priority": "core",
      "value_type": "controlled",
      "unit": null,
      "example_format": "United States"
    },
    {
      "key": "booster_heater_configuration",
      "label": "Booster Heater Configuration",
      "group": "selection",
      "priority": "differentiating",
      "value_type": "controlled",
      "unit": null,
      "example_format": "Integral electric booster, 40 °F rise"
    },
    {
      "key": "ventless_condensing_system",
      "label": "Ventless Condensing System",
      "group": "selection",
      "priority": "differentiating",
      "value_type": "controlled",
      "unit": null,
      "example_format": "No (conventional)"
    },
    {
      "key": "wash_cycle_times",
      "label": "Wash Cycle Times",
      "group": "technical",
      "priority": "differentiating",
      "value_type": "text",
      "unit": "s",
      "example_format": "60 / 90 / 150 (selectable)"
    },
    {
      "key": "installation_orientation",
      "label": "Installation Orientation",
      "group": "fit",
      "priority": "differentiating",
      "value_type": "controlled",
      "unit": null,
      "example_format": "Straight-through or corner (field convertible)"
    },
    {
      "key": "sanitation_certification",
      "label": "Sanitation Certification",
      "group": "evidence",
      "priority": "channel",
      "value_type": "controlled",
      "unit": null,
      "example_format": "NSF/ANSI 3"
    },
    {
      "key": "electrical_safety_listing",
      "label": "Electrical Safety Listing",
      "group": "evidence",
      "priority": "channel",
      "value_type": "controlled",
      "unit": null,
      "example_format": "cULus listed (UL 921)"
    }
  ],
  "evidence_columns": [
    "raw_value",
    "normalized_value",
    "source_uri",
    "source_page_or_row",
    "confidence",
    "review_state",
    "last_verified"
  ],
  "normalization_examples": [
    {
      "attribute": "Sanitizing Method",
      "variants": [
        "High Temp",
        "Hi-Temp",
        "Hot Water Sanitizing",
        "HT",
        "High-Temp w/ Booster",
        "180 Degree"
      ],
      "normalized": "High temperature (hot water sanitizing)"
    },
    {
      "attribute": "Machine Type",
      "variants": [
        "Door Type",
        "Door-Type",
        "Pass-Through",
        "Pass Thru",
        "Hood Type",
        "Upright"
      ],
      "normalized": "Single-tank door type"
    },
    {
      "attribute": "Final Rinse Water Consumption",
      "variants": [
        ".67 gal/rack",
        "0.67 GPR",
        "0.67 gallons per rack",
        "0.67 G/RACK",
        "2.5 L/rack"
      ],
      "normalized": "0.67 gal/rack"
    }
  ]
}
