Building Materials & Lumber · 18 attributes

Drywall and gypsum board product attributes

Drywall attributes to capture: board type, thickness, panel size, edge and facing, the UL type designation for rated assemblies, and mold and abuse ratings.

Download CSV template JSON Editorial reference

Gypsum board catalogs grow quickly because every combination of type, thickness, width, length, edge and facing is its own SKU. Supplier files tend to fold several of those into a product name and leave the rest to a PDF. The result is a catalog where a 5/8 Type X tapered board and a square-edge version sit under one description and get substituted for each other.

Fire-rated work depends on details that the word Type X does not carry. Rated walls and ceilings are tested as assemblies, and those designs name a manufacturer's proprietary board designation rather than a generic type. Without that designation stored per SKU, a buyer cannot tell whether a board belongs in the assembly on the drawings. Moisture, mold and abuse ratings follow separate ASTM test methods that also need their own fields.

Handling data matters on the jobsite. Panel weight, pieces per bundle and whether a product is sold per sheet or per thousand square feet drive delivery, stocking and pricing. Capturing these alongside the technical ratings keeps quotes consistent with how the board is actually shipped.

The drywall attribute template

18 candidate fields in 4 groups, ordered the way a record gets built: identify the item, capture its specifications, then record fit and the evidence behind any claim. 10 are marked Core: without them the item cannot be identified or filtered. Example values show the expected format only; they do not describe a real SKU.

Identity

Which exact item, variant and pack this record describes.

Check before use: Preserve leading zeros and punctuation, validate against the manufacturer record, and check the GTIN check digit and packaging level before linking.

Attribute Type Priority Example format
Brand / Product Line brand_product_line Text Core Example Brand Fire-Rated XP
Manufacturer Part Number (MPN) manufacturer_part_number_mpn Identifier Core GYP-58X-4812-GM
GTIN-14 / UPC gtin_14_upc Identifier Core 10614141330079

Technical specifications

Measured or rated values that must travel with their unit and test conditions.

Check before use: Store the number and unit separately. Convert only when the source unit and test conditions are known.

Attribute Type Priority Example format
Nominal Thickness nominal_thickness Number · in Core 0.625
Panel Width panel_width Number · in Core 48
Panel Length panel_length Number · ft Core 12
Weight per Square Foot weight_per_square_foot Number · lb/sq ft Core 2.3
Mold Resistance Score (ASTM D3273) mold_resistance_score_astm_d3273 Number Buyer decision 10
Abuse & Impact Class (ASTM C1629) abuse_impact_class_astm_c1629 Text Buyer decision Abrasion L3, Indent L2, Soft L3, Hard L1
Maximum Framing Spacing maximum_framing_spacing Number · in o.c. Buyer decision 24
Nail Pull Resistance (ASTM C473) nail_pull_resistance_astm_c473 Number · lbf Buyer decision 87

Selection attributes

The type, material and option choices buyers filter and compare on.

Check before use: Map supplier wording to a governed vocabulary only after checking the source text and which variant it applies to.

Attribute Type Priority Example format
Board Type board_type Controlled list Core Type X
Edge Profile edge_profile Controlled list Core Tapered
Facing Material facing_material Controlled list Core Glass mat

Evidence & compliance

Listings, standards, classifications and origin claims that need a document behind them.

Check before use: Link the manufacturer document or label with its edition or date. Never copy a certification from a neighboring SKU.

Attribute Type Priority Example format
Product Standard Compliance product_standard_compliance Controlled list Channel / evidence ASTM C1658/C1658M
UL Type Designation ul_type_designation Text Channel / evidence Type FR-G (manufacturer designation)
Surface Burning (ASTM E84) surface_burning_astm_e84 Text Channel / evidence Flame spread 0 / Smoke developed 0
Country of Origin country_of_origin Controlled list Channel / evidence United States

Normalize supplier values

The same value arrives in many spellings. Map each raw string to one governed value, and keep the raw text beside it so a reviewer can see what the supplier actually wrote.

Nominal Thickness

5/8"0.625 in5/8 in.15.9 mm5/8inFive-Eighths

Normalized to 0.625 in (15.9 mm)

Board Type

Type XType-XTYPE XTyp XFR Type XFire Rated X

Normalized to Type X

Edge Profile

TaperedTETapered EdgeTaperTap. EdgeT/E

Normalized to Tapered

Often missing from supplier files

These fields are commonly absent from price lists and basic feeds, even though the information usually exists in a datasheet, label or installation manual. Treat an empty value as a request for evidence, not as permission to fill it from a similar model.

  • UL Fire-Resistance Design Numbers
  • Facer Color (face and back paper)
  • Tested Assembly STC
  • Water Vapor Permeance (ASTM E96)
  • Pieces per Bundle / Panels per Lift

Questions the record must answer

Buyers and counter-sales reps choosing drywall ask questions like these. Each one needs a specific field, sourced for the exact variant.

  • Is this the board named in the one-hour wall design on the drawings?
  • Will it hold up in a bathroom or behind tile?
  • Can it span 24 inches on center on a ceiling without sagging?
  • How heavy is one 4x12 sheet for the crew to carry?

From supplier file to record

  1. Resolve identity first. Link the supplier SKU, manufacturer part number and packaging identifiers without merging distinct variants or pack sizes.
  2. Extract with the source attached. Pull values from rows, tables and datasheets, keeping the raw text, unit and page or row reference.
  3. Map to your classification. Assign the ETIM, ECLASS, UNSPSC or internal class your company licenses, and keep the supplier's original terms.
  4. Review, sync and watch. Hold conflicts and safety-related values for a category expert, write approved values to ERP or PIM, and recheck when the supplier sends a new file.

For the full method, see how to build a category attribute template and the category catalog gap audit.

FAQ

Does 'Type X' on its own make a wall fire-rated?

No. Type X is a board classification under ASTM C1396 with enhanced fire resistance, but a fire-resistance rating belongs to a tested assembly of framing, fasteners, board layers and sometimes insulation. Listed designs typically name specific proprietary board designations, not just Type X. Store the manufacturer's UL or other listing type designation per SKU, and optionally the design numbers the manufacturer cites, and rely on the current listing directory for the assembly itself.

What separates Type X from Type C gypsum board in the record?

Both are fire-resistant boards, but Type C is formulated with additional components intended to improve performance in certain assemblies, often ceilings and shaft or area-separation walls. The two are not automatically interchangeable, because a listed design names the board it was tested with. Keep board type as a controlled list with distinct values, and do not map proprietary names to Type C or Type X unless the manufacturer states that classification.

How many SKUs does a single drywall line usually produce?

Often dozens. Multiply thickness by width, several stock lengths, edge profiles and facing options, and a single product line becomes a large variant family, before bundle and lift packaging are counted. Model it as a parent product with variants and give thickness, width, length, edge and facing their own fields so each SKU is distinct. Record the selling unit explicitly, because some channels price by the sheet and others per thousand square feet.

Which ASTM product standard applies to a given panel?

Several standards cover different gypsum products, so store the one the manufacturer states. ASTM C1396 covers gypsum board, including regular, Type X and ceiling board. Glass-mat gypsum panels for interior use are commonly covered by ASTM C1658, glass-mat sheathing and substrates by ASTM C1177, and fiber-reinforced gypsum panels by ASTM C1278. Keep the standard as a controlled evidence field; mixing them in free text hides which tests the panel was made to.

Claro

See where your catalog breaks — free

Claro runs this automatically: resolve identity, fill missing attributes, validate updates, and write clean records back into your PIM/ERP. Upload a sample supplier file for a free catalog audit.

Get a free catalog audit

Related resources

More Building Materials & Lumber templates