Relay attribute template: contact form, coil voltage, contact rating with load type, switching voltage, mounting and agency approvals, with normalization.
Relay records go wrong when the contact rating is stored as a single number. A relay rated 16 A for a resistive load at 250 VAC may be rated far lower for motor, lamp or DC loads, and electrical life depends on the same conditions. Supplier summaries often keep the headline amps and drop the load type and voltage, which leads to relays being specified for loads they were not rated to switch.
Coil and contact data use different vocabularies. Contact form can appear as SPDT, 1 Form C, 1C or changeover, and coil voltage can be written with or without AC or DC. Must-operate and must-release voltages, coil power and latching behavior matter to a designer driving the coil from a controller output, and they are often only in the full datasheet.
Mechanical fit and approvals complete the record. Termination style decides whether the relay goes on a board, a socket or quick-connect wiring, and seal ratings affect whether it survives wave soldering and cleaning. Agency recognition and pilot duty or motor ratings are what panel builders check, so they need to be stored as evidence rather than left in a PDF.
The relays attribute template
18 candidate fields in 5 groups, ordered the way a record gets built: identify the item, capture its specifications, then record fit and the evidence behind any claim. 8 are marked Core: without them the item cannot be identified or filtered. Example values show the expected format only; they do not describe a real SKU.
Identity
Which exact item, variant and pack this record describes.
Check before use: Preserve leading zeros and punctuation, validate against the manufacturer record, and check the GTIN check digit and packaging level before linking.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Manufacturer Part Number (MPN) manufacturer_part_number_mpn | Identifier | Core | PR-1C-24D-16 |
GTIN / UPC gtin_upc | Identifier | Channel / evidence | 00614141000180 |
Technical specifications
Measured or rated values that must travel with their unit and test conditions.
Check before use: Store the number and unit separately. Convert only when the source unit and test conditions are known.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Coil Voltage (Nominal) coil_voltage_nominal | Number · V | Core | 24 VDC |
Contact Rating (Current) contact_rating_current | Number · A | Core | 16 A at 250 VAC, resistive |
Max Switching Voltage max_switching_voltage | Text · V | Core | 250 VAC / 30 VDC |
Coil Power (Nominal) coil_power_nominal | Number · mW | Buyer decision | 400 mW |
Must Operate / Must Release Voltage must_operate_must_release_voltage | Text · % | Buyer decision | Operate ≤ 75 %, release ≥ 10 % of nominal |
Electrical Life at Rated Load electrical_life_at_rated_load | Number · operations | Buyer decision | 100,000 ops at 16 A, 250 VAC, resistive |
Operating Temperature Range operating_temperature_range | Text · °C | Buyer decision | -40 °C to +85 °C |
Selection attributes
The type, material and option choices buyers filter and compare on.
Check before use: Map supplier wording to a governed vocabulary only after checking the source text and which variant it applies to.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Relay Type relay_type | Controlled list | Core | Power relay (over 2 A) |
Contact Form (Contact Arrangement) contact_form_contact_arrangement | Controlled list | Core | 1 Form C (SPDT) |
Coil Type coil_type | Controlled list | Core | Non-latching |
Termination Style termination_style | Controlled list | Buyer decision | PCB pins (solder) |
Contact Material contact_material | Controlled list | Buyer decision | AgSnO2 (silver tin oxide) |
Fit & compatibility
What the item mounts to, mates with, replaces or works alongside.
Check before use: Keep model and series qualifiers. A similar-looking part is not a verified fit until a source says so.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Mounting Type mounting_type | Controlled list | Core | Through hole (PCB) |
Evidence & compliance
Listings, standards, classifications and origin claims that need a document behind them.
Check before use: Link the manufacturer document or label with its edition or date. Never copy a certification from a neighboring SKU.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Contact Rating Code (Pilot Duty / TV / HP) contact_rating_code_pilot_duty_tv_hp | Text | Channel / evidence | B300 pilot duty; 1/2 HP at 120 VAC |
Agency Approvals & File Number agency_approvals_file_number | Text | Channel / evidence | UL Recognized (file number as listed); CSA C22.2 No. 14; EN 61810-1 |
RoHS / REACH Status rohs_reach_status | Controlled list | Channel / evidence | RoHS compliant; no SVHC above 0.1% w/w |
Normalize supplier values
The same value arrives in many spellings. Map each raw string to one governed value, and keep the raw text beside it so a reviewer can see what the supplier actually wrote.
Contact Form (Contact Arrangement)
SPDT1 Form C1CCO1 changeoverSPDT (1 Form C) Normalized to 1 Form C (SPDT)
Coil Voltage (Nominal)
24VDC24 V DCDC24V24 Vdc24 V=DC 24 V Normalized to 24 VDC
Contact Material
AgSnO2Silver Tin OxideAg/SnO2AgSnO²AgSnO2 contactsSilver-tin-oxide Normalized to AgSnO2 (silver tin oxide)
Often missing from supplier files
These fields are commonly absent from price lists and basic feeds, even though the information usually exists in a datasheet, label or installation manual. Treat an empty value as a request for evidence, not as permission to fill it from a similar model.
- Seal Rating (IEC 61810-7 category)
- Must Operate / Must Release Voltage
- Contact Rating by Load Type (pilot duty, motor, lamp)
- Coil Power at Nominal Voltage
- Load Conditions for the Electrical Life Figure
Questions the record must answer
Buyers and counter-sales reps choosing relays ask questions like these. Each one needs a specific field, sourced for the exact variant.
- Can this relay switch a 1/2 HP motor at 120 VAC, or only resistive loads?
- Will a 24 VDC controller output pull this coil in reliably?
- Does this relay fit the socket already in my panel?
- Is this relay UL recognized with a pilot duty rating?
From supplier file to record
- Resolve identity first. Link the supplier SKU, manufacturer part number and packaging identifiers without merging distinct variants or pack sizes.
- Extract with the source attached. Pull values from rows, tables and datasheets, keeping the raw text, unit and page or row reference.
- Map to your classification. Assign the ETIM, ECLASS, UNSPSC or internal class your company licenses, and keep the supplier's original terms.
- Review, sync and watch. Hold conflicts and safety-related values for a category expert, write approved values to ERP or PIM, and recheck when the supplier sends a new file.
For the full method, see how to build a category attribute template and the category catalog gap audit.
FAQ
Why is a single contact current rating not enough?
A relay's contact rating depends on the load type, the voltage and whether it is AC or DC. The same contacts can be rated much lower for inductive loads such as motors and solenoids, or for DC switching where arcs are harder to break. Store contact ratings as structured rows with current, voltage, AC or DC, and load type such as resistive, inductive, motor or lamp, and keep electrical life with the load it was measured at. Use the manufacturer's datasheet and agency listing as the source.
What does a relay seal rating tell a buyer, and where should it go?
Seal rating describes how well the relay case is protected, for example whether it is flux-tight for soldering or sealed well enough to be washed after assembly. IEC 61810-7 defines categories such as RT II and RT III, and manufacturers also use their own terms. Store it as a controlled value with the standard it references, taken from the manufacturer's documentation. It helps a buyer confirm the relay suits the board assembly process.
How should contact form be normalized across suppliers?
Pick one governed value per arrangement and map the common spellings to it. For example, SPDT, 1C, 1 Form C, CO and changeover all describe one single-pole changeover contact. Store the pole count and the Form A, B or C type as structured fields and generate the display label from them. This avoids mismatches such as 2 Form C and DPDT being listed as different products. Keep the supplier's original text as a source value for traceability.
When does a relay need force-guided contact data on the record?
Force-guided, or mechanically linked, contacts are used in safety circuits where a welded normally open contact must prevent the normally closed contact from closing. Relays with this feature are made and certified to EN 61810-3, and buyers in machine safety look for it explicitly. Store it as a controlled evidence field that is set only when the manufacturer's documentation states conformance. Whether a relay is suitable for a given safety function is a system design decision, not a catalog attribute.
Claro
See where your catalog breaks — free
Claro runs this automatically: resolve identity, fill missing attributes, validate updates, and write clean records back into your PIM/ERP. Upload a sample supplier file for a free catalog audit.
Get a free catalog auditRelated resources
Comparisons
UL vs CE Marking: Certification Data in Product Records
UL vs CE compared for industrial product records: what each mark means, where it applies, and which certification fields distributors should structure.
Free Tools
RoHS Compliance Checker
Free RoHS compliance checker: paste a product's substance data and get an instant pass/fail against the 10 RoHS-restricted substances. Runs in your browser.
Free Tools
MPN Normalizer
Free in-browser tool to normalize manufacturer part numbers — strip noise, standardize formatting, and surface duplicate parts. No upload, no login.