Foodservice Equipment & Supply · 18 attributes
Commercial dishwasher product attributes
Product data fields for commercial dishwashers: machine type, sanitizing method, racks per hour, rinse water per rack, booster heater and electrical supply.
A commercial dishwasher record has to answer installation questions as well as performance ones. Supplier data tends to lead with racks per hour and leave the rest in a spec sheet: incoming water temperature and pressure, booster heater rise, drain requirements and electrical load. Those values change with the sanitizing method, because a high-temperature machine needs a booster or very hot supply water, while a chemical machine relies on a sanitizer dose at a lower temperature.
One model is often sold in several electrical configurations, with and without a booster, and in straight-through or corner layouts. Each changes the connected load, the circuit size and sometimes the footprint, so each orderable configuration needs its own record. Rack size is a compatibility field as much as a dimension: most door-type and conveyor machines take the standard 20 x 20 in rack, and the record should say so rather than leave it implied.
Performance numbers need context. Racks per hour is usually calculated from the shortest cycle, and rinse water per rack depends on the cycle chosen. Storing the cycle times next to these figures, together with the sanitation and electrical listings, lets a buyer compare machines on the same terms.
The commercial dishwashers attribute template
18 candidate fields in 5 groups, ordered the way a record gets built: identify the item, capture its specifications, then record fit and the evidence behind any claim. 12 are marked Core: without them the item cannot be identified or filtered. Example values show the expected format only; they do not describe a real SKU.
Identity
Which exact item, variant and pack this record describes.
Check before use: Preserve leading zeros and punctuation, validate against the manufacturer record, and check the GTIN check digit and packaging level before linking.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Manufacturer Part Number (MPN) manufacturer_part_number_mpn | Identifier | Core | DT-60HT-3P |
GTIN-14 / UPC-A gtin_14_upc_a | Identifier | Core | 10012345600309 |
Technical specifications
Measured or rated values that must travel with their unit and test conditions.
Check before use: Store the number and unit separately. Convert only when the source unit and test conditions are known.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Capacity, Racks Per Hour capacity_racks_per_hour | Number · racks/h | Core | 55 |
Electrical Supply (Voltage / Hz / Phase) electrical_supply_voltage_hz_phase | Controlled list | Core | 208-240 V / 60 Hz / 3 Ph |
Total Connected Load total_connected_load | Number · kW | Core | 17.2 |
Final Rinse Water Consumption final_rinse_water_consumption | Number · gal/rack | Core | 0.74 |
Incoming Water Supply Requirement incoming_water_supply_requirement | Text | Core | 140 °F min supply; 20 ± 5 psi flowing; 4 gr/gal max hardness |
Overall Dimensions (W x D x H) overall_dimensions_w_x_d_x_h | Text · in | Core | 25-1/4 x 29-1/2 x 66-3/4 in (door closed) |
Wash Cycle Times wash_cycle_times | Text · s | Buyer decision | 60 / 90 / 150 (selectable) |
Selection attributes
The type, material and option choices buyers filter and compare on.
Check before use: Map supplier wording to a governed vocabulary only after checking the source text and which variant it applies to.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Machine Type machine_type | Controlled list | Core | Single-tank door type |
Sanitizing Method sanitizing_method | Controlled list | Core | High temperature (hot water sanitizing) |
Booster Heater Configuration booster_heater_configuration | Controlled list | Buyer decision | Integral electric booster, 40 °F rise |
Ventless Condensing System ventless_condensing_system | Controlled list | Buyer decision | No (conventional) |
Fit & compatibility
What the item mounts to, mates with, replaces or works alongside.
Check before use: Keep model and series qualifiers. A similar-looking part is not a verified fit until a source says so.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Rack Size Accepted rack_size_accepted | Controlled list | Core | 19-3/4 x 19-3/4 in (standard 20 x 20 in rack) |
Installation Orientation installation_orientation | Controlled list | Buyer decision | Straight-through or corner (field convertible) |
Evidence & compliance
Listings, standards, classifications and origin claims that need a document behind them.
Check before use: Link the manufacturer document or label with its edition or date. Never copy a certification from a neighboring SKU.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Country of Origin country_of_origin | Controlled list | Core | United States |
Sanitation Certification sanitation_certification | Controlled list | Channel / evidence | NSF/ANSI 3 |
Electrical Safety Listing electrical_safety_listing | Controlled list | Channel / evidence | cULus listed (UL 921) |
Normalize supplier values
The same value arrives in many spellings. Map each raw string to one governed value, and keep the raw text beside it so a reviewer can see what the supplier actually wrote.
Sanitizing Method
High TempHi-TempHot Water SanitizingHTHigh-Temp w/ Booster180 Degree Normalized to High temperature (hot water sanitizing)
Machine Type
Door TypeDoor-TypePass-ThroughPass ThruHood TypeUpright Normalized to Single-tank door type
Final Rinse Water Consumption
.67 gal/rack0.67 GPR0.67 gallons per rack0.67 G/RACK2.5 L/rack Normalized to 0.67 gal/rack
Often missing from supplier files
These fields are commonly absent from price lists and basic feeds, even though the information usually exists in a datasheet, label or installation manual. Treat an empty value as a request for evidence, not as permission to fill it from a similar model.
- Heat Gain to Space (Latent and Sensible, BTU/h)
- Booster Heater Temperature Rise (°F)
- Idle Energy Rate (kW) and Washing Energy (kWh/rack)
- Minimum Circuit Ampacity (MCA)
- Peak Drain Flow Rate (gal/min)
Questions the record must answer
Buyers and counter-sales reps choosing commercial dishwashers ask questions like these. Each one needs a specific field, sourced for the exact variant.
- Will this machine run on our existing 208 V three-phase circuit?
- Do we still need a booster heater if our building supplies 140 °F water?
- Can it be installed in a corner layout with our current soiled dish table?
- How much water does it use per rack on the normal cycle?
From supplier file to record
- Resolve identity first. Link the supplier SKU, manufacturer part number and packaging identifiers without merging distinct variants or pack sizes.
- Extract with the source attached. Pull values from rows, tables and datasheets, keeping the raw text, unit and page or row reference.
- Map to your classification. Assign the ETIM, ECLASS, UNSPSC or internal class your company licenses, and keep the supplier's original terms.
- Review, sync and watch. Hold conflicts and safety-related values for a category expert, write approved values to ERP or PIM, and recheck when the supplier sends a new file.
For the full method, see how to build a category attribute template and the category catalog gap audit.
FAQ
What changes in the record between high-temperature and chemical-sanitizing machines?
The sanitizing method drives several other fields. A high-temperature machine needs final rinse temperature, booster heater type and rise, and required supply water temperature, and it usually carries a higher electrical load. A chemical machine needs sanitizer type, dosing or pump details and the required wash and rinse temperatures, and often has no booster. Make sanitizing method a controlled field and use it to decide which dependent fields are required, so a chemical unit is not marked incomplete for missing a booster rating.
Why do racks-per-hour figures not compare well across brands?
Most published figures are the theoretical maximum at the shortest cycle, ignoring loading time, and some suppliers use a longer or heavy-soil cycle. Store racks per hour as a number together with the cycle time it assumes, and keep each selectable cycle time in its own field. Final rinse water per rack should be stored the same way. With the basis recorded, a buyer can compare like with like, and figures quoted per hour can be converted without guessing.
Which standards apply to a commercial dishwasher?
Sanitation performance for commercial warewashing equipment is usually certified to NSF/ANSI 3, and electrical safety in North America to UL 921 or the corresponding Canadian standard, often shown as a cULus or ETL listing. Energy and water efficiency may be covered by ENERGY STAR for eligible machine types. Store each as a separate evidence field with the certifier and reference, and rely on the manufacturer's current listings, since certifications can differ between electrical configurations of the same model.
What should a record say before a machine is called ventless?
Ventless usually means the machine has a built-in condensing or heat-recovery system that reduces vapor release at the door, so it may not need a separate exhaust hood. Whether a hood is actually required is decided by the local authority having jurisdiction, based on the machine's listing and local code. Store ventless as a controlled field backed by the manufacturer's documentation, record the system type, and do not describe a unit as hood-free unless the manufacturer states it.
Claro
See where your catalog breaks — free
Claro runs this automatically: resolve identity, fill missing attributes, validate updates, and write clean records back into your PIM/ERP. Upload a sample supplier file for a free catalog audit.
Get a free catalog auditRelated resources
Playbooks
Extract Product Specs From PDFs With Full Traceability
How to extract product specs from PDF datasheets into structured attributes while keeping a source link for every value — auditable and PIM-ready.
Playbooks
How to Group Product Variants Into One Family
A cable gland in five sizes shouldn't be five unrelated catalog entries. Here's how to structure variants so search, filtering, and inventory all make sense.
Glossary
What Is Unit of Measure (UOM) in Product Data?
UOM errors silently corrupt pricing, matching, and AI search. Learn how unit of measure works, why it breaks, and how to fix it across supplier feeds.
Free Tools
Unit & Dimension Converter
Free product dimension converter from Claro. Convert length, weight, volume and pack dimensions between metric and imperial in your browser. No upload.