Pool, Spa & Irrigation · 18 attributes
Irrigation valve product attributes
Product data fields for irrigation control valves: size and end connections, solenoid voltage, flow range, pressure loss at design flow, and body pattern.
Irrigation control valves are sold in families where one base model spawns many SKUs through option suffixes: flow control, pressure regulation, reclaimed-water trim, different connections and different solenoids. Supplier price lists often show the suffix code and little else, so the catalog has to translate each code into attributes a buyer can filter on.
The solenoid is a frequent source of wrong orders. Most residential and commercial controllers drive 24 VAC solenoids, while battery-operated controllers need DC latching solenoids that are not interchangeable with them. Connection data is similar: female NPT, slip and BSP threads can appear on visually identical bodies sold in different regions.
Hydraulic data decides whether a valve suits a zone. Flow range says what the valve can control, but pressure loss at the design flow says how much pressure is left for the heads downstream. Many supplier files carry the first and omit the second, which sits in a manufacturer's friction loss table.
The irrigation valves attribute template
18 candidate fields in 5 groups, ordered the way a record gets built: identify the item, capture its specifications, then record fit and the evidence behind any claim. 11 are marked Core: without them the item cannot be identified or filtered. Example values show the expected format only; they do not describe a real SKU.
Identity
Which exact item, variant and pack this record describes.
Check before use: Preserve leading zeros and punctuation, validate against the manufacturer record, and check the GTIN check digit and packaging level before linking.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Manufacturer Part Number (MPN) manufacturer_part_number_mpn | Identifier | Core | IV-100-FC |
GTIN / UPC gtin_upc | Identifier | Core | 012345100109 |
Technical specifications
Measured or rated values that must travel with their unit and test conditions.
Check before use: Store the number and unit separately. Convert only when the source unit and test conditions are known.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Nominal Valve Size nominal_valve_size | Controlled list · in | Core | 1 in (DN 25) |
Operating Pressure Range operating_pressure_range | Text · psi | Core | 20-150 psi (1.4-10.3 bar) |
Flow Range flow_range | Text · gpm | Core | 0.2-40 gpm (0.8-150 L/min) |
Pressure Loss at Design Flow pressure_loss_at_design_flow | Number · psi | Buyer decision | 4.8 psi at 30 gpm |
Selection attributes
The type, material and option choices buyers filter and compare on.
Check before use: Map supplier wording to a governed vocabulary only after checking the source text and which variant it applies to.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Body Pattern body_pattern | Controlled list | Core | Globe / angle (convertible body) |
Actuation Type & Fail State actuation_type_fail_state | Controlled list | Core | Electric solenoid, normally closed |
Body Material body_material | Controlled list | Core | Glass-filled nylon |
Diaphragm Material diaphragm_material | Controlled list | Core | Fabric-reinforced nitrile (Buna-N) |
Flow Control flow_control | Controlled list | Buyer decision | Yes, external flow control handle |
Pressure Regulation pressure_regulation | Controlled list | Buyer decision | Optional module, 15-100 psi, ordered separately |
Debris Handling debris_handling | Controlled list | Buyer decision | Self-flushing stainless steel filter screen |
Reclaimed-Water (Non-Potable) Configuration reclaimed_water_non_potable_configuration | Controlled list | Channel / evidence | Purple handle, chlorine-resistant diaphragm |
Fit & compatibility
What the item mounts to, mates with, replaces or works alongside.
Check before use: Keep model and series qualifiers. A similar-looking part is not a verified fit until a source says so.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Inlet x Outlet Connection inlet_x_outlet_connection | Controlled list | Core | 1 in FNPT x 1 in FNPT |
Solenoid Rating solenoid_rating | Controlled list | Core | 24 VAC, 50/60 Hz |
Evidence & compliance
Listings, standards, classifications and origin claims that need a document behind them.
Check before use: Link the manufacturer document or label with its edition or date. Never copy a certification from a neighboring SKU.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Anti-Siphon / Backflow Listing anti_siphon_backflow_listing | Controlled list | Channel / evidence | None (in-line valve; separate backflow assembly required) |
Country of Origin country_of_origin | Controlled list | Channel / evidence | Mexico |
Normalize supplier values
The same value arrives in many spellings. Map each raw string to one governed value, and keep the raw text beside it so a reviewer can see what the supplier actually wrote.
Nominal Valve Size
1"1 in1.0 IN25mmDN251 inch Normalized to 1 in (DN 25)
Solenoid Rating
24V24 VAC24VAC 60Hz24 volt AC24VAC 50/6024 V AC Normalized to 24 VAC, 50/60 Hz
Inlet x Outlet Connection
FNPTFIPTF.I.P.T.1" FPTFemale NPT1" FIPT x FIPT Normalized to 1 in FNPT x 1 in FNPT
Often missing from supplier files
These fields are commonly absent from price lists and basic feeds, even though the information usually exists in a datasheet, label or installation manual. Treat an empty value as a request for evidence, not as permission to fill it from a similar model.
- Solenoid inrush and holding current
- Pressure regulation: whether a module is included, and its range
- Reclaimed-water (non-potable) configuration
- Bonnet access type (jar-top vs bolted)
- Installed dimensions (H x L x W)
Questions the record must answer
Buyers and counter-sales reps choosing irrigation valves ask questions like these. Each one needs a specific field, sourced for the exact variant.
- Will this 1 inch valve handle a 25 gpm zone without losing too much pressure?
- Will it work with my battery-powered controller, or does it need 24 VAC?
- Does it have flow control so I can throttle the zone?
- Is there a purple reclaimed-water version for our recycled water system?
From supplier file to record
- Resolve identity first. Link the supplier SKU, manufacturer part number and packaging identifiers without merging distinct variants or pack sizes.
- Extract with the source attached. Pull values from rows, tables and datasheets, keeping the raw text, unit and page or row reference.
- Map to your classification. Assign the ETIM, ECLASS, UNSPSC or internal class your company licenses, and keep the supplier's original terms.
- Review, sync and watch. Hold conflicts and safety-related values for a category expert, write approved values to ERP or PIM, and recheck when the supplier sends a new file.
For the full method, see how to build a category attribute template and the category catalog gap audit.
FAQ
Do irrigation valves need lead-free or NSF/ANSI 61 certification?
It depends on where the valve sits and what local code requires. Valves installed downstream of a backflow preventer on a non-potable irrigation line are often treated differently from products in contact with drinking water, but requirements vary by jurisdiction. Store any lead-free or drinking water certification as its own evidence field, filled only when the manufacturer's current documentation or the certifier's listing states it, and leave the field empty rather than implying compliance.
Should globe and angle versions be one SKU or two?
Follow how the manufacturer sells them. When one body converts between globe and angle flow, it is a single SKU and the body pattern value should say convertible. When globe and angle are separate bodies with their own part numbers, they are separate SKUs that share a family. In both cases keep body pattern as a controlled field, because it decides how the valve fits into a manifold or a valve box.
If a record already has a flow range, why also store pressure loss?
Flow range tells you the valve can control a given flow; it does not tell you what that flow costs in pressure. A valve at the top of its range can drop enough pressure to leave the sprinkler heads below their operating range. Store pressure loss as a number tied to a stated flow, or as a small table of flow and loss pairs from the manufacturer's data, so a designer can check the zone without opening a PDF.
How should valve option suffixes be modeled in the catalog?
Treat the suffix as a code that maps to attributes, not as the attribute itself. Keep a lookup table per manufacturer that translates each suffix into values such as flow control present, pressure regulation included, reclaimed-water trim and solenoid type. Apply that table at intake so every SKU carries the decoded fields, and keep the full part number as the identifier so the original code is never lost.
Claro
See where your catalog breaks — free
Claro runs this automatically: resolve identity, fill missing attributes, validate updates, and write clean records back into your PIM/ERP. Upload a sample supplier file for a free catalog audit.
Get a free catalog auditRelated resources
Comparisons
NPT vs BSP vs Metric Threads: Side-by-Side Comparison
NPT vs BSP threads vs metric compared side by side: taper, sealing, sizing, and how to enrich thread attributes cleanly in a product catalog.
Free Tools
Thread Size Cross-Reference
Free thread size cross reference: paste a thread callout and map metric, UNC/UNF, BSP/BSPT, and NPT designations. Runs in your browser, no upload.
Guides
Product Data Management for Plumbing Distribution
Plumbing catalogs mix dozens of manufacturers, regional standards, and compatibility rules that aren't obvious from a part number. Here's what makes this vertical distinct.
Playbooks
How to Group Product Variants Into One Family
A cable gland in five sizes shouldn't be five unrelated catalog entries. Here's how to structure variants so search, filtering, and inventory all make sense.