Pool, Spa & Irrigation · 18 attributes

Irrigation valve product attributes

Product data fields for irrigation control valves: size and end connections, solenoid voltage, flow range, pressure loss at design flow, and body pattern.

Download CSV template JSON Editorial reference

Irrigation control valves are sold in families where one base model spawns many SKUs through option suffixes: flow control, pressure regulation, reclaimed-water trim, different connections and different solenoids. Supplier price lists often show the suffix code and little else, so the catalog has to translate each code into attributes a buyer can filter on.

The solenoid is a frequent source of wrong orders. Most residential and commercial controllers drive 24 VAC solenoids, while battery-operated controllers need DC latching solenoids that are not interchangeable with them. Connection data is similar: female NPT, slip and BSP threads can appear on visually identical bodies sold in different regions.

Hydraulic data decides whether a valve suits a zone. Flow range says what the valve can control, but pressure loss at the design flow says how much pressure is left for the heads downstream. Many supplier files carry the first and omit the second, which sits in a manufacturer's friction loss table.

The irrigation valves attribute template

18 candidate fields in 5 groups, ordered the way a record gets built: identify the item, capture its specifications, then record fit and the evidence behind any claim. 11 are marked Core: without them the item cannot be identified or filtered. Example values show the expected format only; they do not describe a real SKU.

Identity

Which exact item, variant and pack this record describes.

Check before use: Preserve leading zeros and punctuation, validate against the manufacturer record, and check the GTIN check digit and packaging level before linking.

Attribute Type Priority Example format
Manufacturer Part Number (MPN) manufacturer_part_number_mpn Identifier Core IV-100-FC
GTIN / UPC gtin_upc Identifier Core 012345100109

Technical specifications

Measured or rated values that must travel with their unit and test conditions.

Check before use: Store the number and unit separately. Convert only when the source unit and test conditions are known.

Attribute Type Priority Example format
Nominal Valve Size nominal_valve_size Controlled list · in Core 1 in (DN 25)
Operating Pressure Range operating_pressure_range Text · psi Core 20-150 psi (1.4-10.3 bar)
Flow Range flow_range Text · gpm Core 0.2-40 gpm (0.8-150 L/min)
Pressure Loss at Design Flow pressure_loss_at_design_flow Number · psi Buyer decision 4.8 psi at 30 gpm

Selection attributes

The type, material and option choices buyers filter and compare on.

Check before use: Map supplier wording to a governed vocabulary only after checking the source text and which variant it applies to.

Attribute Type Priority Example format
Body Pattern body_pattern Controlled list Core Globe / angle (convertible body)
Actuation Type & Fail State actuation_type_fail_state Controlled list Core Electric solenoid, normally closed
Body Material body_material Controlled list Core Glass-filled nylon
Diaphragm Material diaphragm_material Controlled list Core Fabric-reinforced nitrile (Buna-N)
Flow Control flow_control Controlled list Buyer decision Yes, external flow control handle
Pressure Regulation pressure_regulation Controlled list Buyer decision Optional module, 15-100 psi, ordered separately
Debris Handling debris_handling Controlled list Buyer decision Self-flushing stainless steel filter screen
Reclaimed-Water (Non-Potable) Configuration reclaimed_water_non_potable_configuration Controlled list Channel / evidence Purple handle, chlorine-resistant diaphragm

Fit & compatibility

What the item mounts to, mates with, replaces or works alongside.

Check before use: Keep model and series qualifiers. A similar-looking part is not a verified fit until a source says so.

Attribute Type Priority Example format
Inlet x Outlet Connection inlet_x_outlet_connection Controlled list Core 1 in FNPT x 1 in FNPT
Solenoid Rating solenoid_rating Controlled list Core 24 VAC, 50/60 Hz

Evidence & compliance

Listings, standards, classifications and origin claims that need a document behind them.

Check before use: Link the manufacturer document or label with its edition or date. Never copy a certification from a neighboring SKU.

Attribute Type Priority Example format
Anti-Siphon / Backflow Listing anti_siphon_backflow_listing Controlled list Channel / evidence None (in-line valve; separate backflow assembly required)
Country of Origin country_of_origin Controlled list Channel / evidence Mexico

Normalize supplier values

The same value arrives in many spellings. Map each raw string to one governed value, and keep the raw text beside it so a reviewer can see what the supplier actually wrote.

Nominal Valve Size

1"1 in1.0 IN25mmDN251 inch

Normalized to 1 in (DN 25)

Solenoid Rating

24V24 VAC24VAC 60Hz24 volt AC24VAC 50/6024 V AC

Normalized to 24 VAC, 50/60 Hz

Inlet x Outlet Connection

FNPTFIPTF.I.P.T.1" FPTFemale NPT1" FIPT x FIPT

Normalized to 1 in FNPT x 1 in FNPT

Often missing from supplier files

These fields are commonly absent from price lists and basic feeds, even though the information usually exists in a datasheet, label or installation manual. Treat an empty value as a request for evidence, not as permission to fill it from a similar model.

  • Solenoid inrush and holding current
  • Pressure regulation: whether a module is included, and its range
  • Reclaimed-water (non-potable) configuration
  • Bonnet access type (jar-top vs bolted)
  • Installed dimensions (H x L x W)

Questions the record must answer

Buyers and counter-sales reps choosing irrigation valves ask questions like these. Each one needs a specific field, sourced for the exact variant.

  • Will this 1 inch valve handle a 25 gpm zone without losing too much pressure?
  • Will it work with my battery-powered controller, or does it need 24 VAC?
  • Does it have flow control so I can throttle the zone?
  • Is there a purple reclaimed-water version for our recycled water system?

From supplier file to record

  1. Resolve identity first. Link the supplier SKU, manufacturer part number and packaging identifiers without merging distinct variants or pack sizes.
  2. Extract with the source attached. Pull values from rows, tables and datasheets, keeping the raw text, unit and page or row reference.
  3. Map to your classification. Assign the ETIM, ECLASS, UNSPSC or internal class your company licenses, and keep the supplier's original terms.
  4. Review, sync and watch. Hold conflicts and safety-related values for a category expert, write approved values to ERP or PIM, and recheck when the supplier sends a new file.

For the full method, see how to build a category attribute template and the category catalog gap audit.

FAQ

Do irrigation valves need lead-free or NSF/ANSI 61 certification?

It depends on where the valve sits and what local code requires. Valves installed downstream of a backflow preventer on a non-potable irrigation line are often treated differently from products in contact with drinking water, but requirements vary by jurisdiction. Store any lead-free or drinking water certification as its own evidence field, filled only when the manufacturer's current documentation or the certifier's listing states it, and leave the field empty rather than implying compliance.

Should globe and angle versions be one SKU or two?

Follow how the manufacturer sells them. When one body converts between globe and angle flow, it is a single SKU and the body pattern value should say convertible. When globe and angle are separate bodies with their own part numbers, they are separate SKUs that share a family. In both cases keep body pattern as a controlled field, because it decides how the valve fits into a manifold or a valve box.

If a record already has a flow range, why also store pressure loss?

Flow range tells you the valve can control a given flow; it does not tell you what that flow costs in pressure. A valve at the top of its range can drop enough pressure to leave the sprinkler heads below their operating range. Store pressure loss as a number tied to a stated flow, or as a small table of flow and loss pairs from the manufacturer's data, so a designer can check the zone without opening a PDF.

How should valve option suffixes be modeled in the catalog?

Treat the suffix as a code that maps to attributes, not as the attribute itself. Keep a lookup table per manufacturer that translates each suffix into values such as flow control present, pressure regulation included, reclaimed-water trim and solenoid type. Apply that table at intake so every SKU carries the decoded fields, and keep the full part number as the identifier so the original code is never lost.

Claro

See where your catalog breaks — free

Claro runs this automatically: resolve identity, fill missing attributes, validate updates, and write clean records back into your PIM/ERP. Upload a sample supplier file for a free catalog audit.

Get a free catalog audit

Related resources

More Pool, Spa & Irrigation templates