Pool, Spa & Irrigation · 18 attributes
Pool pump product attributes
Product data fields for pool pumps: total horsepower, speed control, suction and discharge port size, voltage, and weighted energy factor (WEF).
Pool pump horsepower is one of the least consistent values in any catalog. A pump may be described by rated horsepower, by service factor, or by total horsepower, which multiplies the two, and suppliers mix these freely. Because replacement pumps are chosen partly by matching horsepower, a record that does not say which figure it holds leads directly to oversized or undersized pumps.
Energy regulation adds a second layer. Dedicated-purpose pool pumps covered by federal rules carry a weighted energy factor, and utility rebates and state programs often depend on that value or on a listing. Many supplier files omit it or store it as a yes or no flag.
Plumbing and control details decide whether a pump drops into an existing pad. Suction and discharge ports can differ in size, voltage may be single or dual, and variable-speed pumps may or may not talk to an existing automation system. The same pump may also exist as several SKUs for different sales channels.
The pool pumps attribute template
18 candidate fields in 5 groups, ordered the way a record gets built: identify the item, capture its specifications, then record fit and the evidence behind any claim. 11 are marked Core: without them the item cannot be identified or filtered. Example values show the expected format only; they do not describe a real SKU.
Identity
Which exact item, variant and pack this record describes.
Check before use: Preserve leading zeros and punctuation, validate against the manufacturer record, and check the GTIN check digit and packaging level before linking.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Manufacturer Part Number manufacturer_part_number | Identifier | Core | VSP-165-2 |
GTIN / UPC gtin_upc | Identifier | Core | 012345165207 |
Technical specifications
Measured or rated values that must travel with their unit and test conditions.
Check before use: Store the number and unit separately. Convert only when the source unit and test conditions are known.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Total Horsepower (THP) total_horsepower_thp | Number · hp | Core | 1.65 |
Voltage voltage | Controlled list · V | Core | 115/230 V (dual) |
Phase phase | Controlled list | Core | Single |
Full Load Amps full_load_amps | Text · A | Core | 10.0 A max at 230 V |
Weighted Energy Factor (WEF) weighted_energy_factor_wef | Number · kgal/kWh | Buyer decision | 9.3 |
Max Flow Rate max_flow_rate | Number · gpm | Buyer decision | 150 (at 30 ft TDH) |
Performance Curve (Flow vs Head by RPM) performance_curve_flow_vs_head_by_rpm | Text | Buyer decision | gpm vs head (ft) at 1,000 / 1,500 / 2,400 / 3,450 rpm |
Selection attributes
The type, material and option choices buyers filter and compare on.
Check before use: Map supplier wording to a governed vocabulary only after checking the source text and which variant it applies to.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Pump Type pump_type | Controlled list | Core | Self-priming pool filter pump |
Speed Control speed_control | Controlled list | Core | Variable speed |
Fit & compatibility
What the item mounts to, mates with, replaces or works alongside.
Check before use: Keep model and series qualifiers. A similar-looking part is not a verified fit until a source says so.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Pool Application pool_application | Controlled list | Core | In-ground |
Suction Port Size suction_port_size | Number · in | Core | 2 |
Discharge Port Size discharge_port_size | Number · in | Core | 2 |
Automation Protocol automation_protocol | Controlled list | Buyer decision | RS-485 |
Evidence & compliance
Listings, standards, classifications and origin claims that need a document behind them.
Check before use: Link the manufacturer document or label with its edition or date. Never copy a certification from a neighboring SKU.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
ENERGY STAR Certified energy_star_certified | Controlled list | Channel / evidence | Yes |
CEC Title 20 / MAEDbS Listed cec_title_20_maedbs_listed | Controlled list | Channel / evidence | Yes |
Country of Origin country_of_origin | Controlled list | Channel / evidence | Mexico |
Normalize supplier values
The same value arrives in many spellings. Map each raw string to one governed value, and keep the raw text beside it so a reviewer can see what the supplier actually wrote.
Port Size
2 in.2 in2.0 in.2"2 INCH50 mm Normalized to 2 in
Total Horsepower (THP)
1.65 THP1.65 total HP1.65 HP (THP)1.5 HP x 1.1 SF1.0 HP, 1.65 SFTHP 1.65 Normalized to 1.65 THP
Voltage
115/230V115V/230V115-230V115 / 230 VAC110-120/220-240Dual Voltage 115/230 Normalized to 115/230 V (dual)
Often missing from supplier files
These fields are commonly absent from price lists and basic feeds, even though the information usually exists in a datasheet, label or installation manual. Treat an empty value as a request for evidence, not as permission to fill it from a similar model.
- Weighted energy factor (WEF)
- Discharge port size, separate from suction
- Sales channel and warranty terms
- Automation protocol / control compatibility
- Performance curve data (flow vs head by rpm)
Questions the record must answer
Buyers and counter-sales reps choosing pool pumps ask questions like these. Each one needs a specific field, sourced for the exact variant.
- Will this replace my old 1.5 HP single-speed pump and qualify for the utility rebate?
- Can it run on the 115 V circuit I have, or do I need to rewire for 230 V?
- Will my existing automation system control its speeds?
- Are both ports 2 inch, or will I need a reducer on the discharge side?
From supplier file to record
- Resolve identity first. Link the supplier SKU, manufacturer part number and packaging identifiers without merging distinct variants or pack sizes.
- Extract with the source attached. Pull values from rows, tables and datasheets, keeping the raw text, unit and page or row reference.
- Map to your classification. Assign the ETIM, ECLASS, UNSPSC or internal class your company licenses, and keep the supplier's original terms.
- Review, sync and watch. Hold conflicts and safety-related values for a category expert, write approved values to ERP or PIM, and recheck when the supplier sends a new file.
For the full method, see how to build a category attribute template and the category catalog gap audit.
FAQ
Why is the same pump listed as 1.0 HP, 1.5 HP and 1.65 THP?
Each number is a different measure. Rated horsepower is the nameplate value, the service factor allows sustained operation above it, and total horsepower is rated horsepower multiplied by service factor. A 1.5 HP motor with a 1.1 service factor and a 1.0 HP motor with a 1.65 service factor both come out at 1.65 THP. Store rated horsepower, service factor and THP as separate numeric fields, and only compute THP when both inputs come from the same source.
Does every pool pump record need a WEF value?
WEF applies to dedicated-purpose pool pumps covered by federal energy conservation rules, and whether a given model is covered depends on its type and size. Make the field conditionally required, record the value exactly as the manufacturer certified it in kgal/kWh, and when a pump is not covered, store that status with a reason instead of leaving the field blank. Rely on the manufacturer's documentation and the DOE compliance database rather than calculating WEF from other data.
Should suction and discharge port size be one field or two?
Two. Many pumps share a size on both sides, but some have a larger suction than discharge, or offer different port sizes through union kits. A single port size field forces a guess when they differ, and that guess becomes a missing reducer on the job. Store each as its own numeric field in inches, and add the connection type, such as threaded or union, when the manufacturer states it.
How should channel-specific SKUs of the same pump be handled?
Manufacturers sometimes sell an otherwise identical pump under different part numbers for different sales channels, often with different warranty terms. Keep each part number as its own SKU, link them to a shared base model so technical attributes are maintained once, and store channel and warranty terms as separate fields. That lets a counter rep see that two items are physically the same while still quoting the one the customer is authorized to buy.
Claro
See where your catalog breaks — free
Claro runs this automatically: resolve identity, fill missing attributes, validate updates, and write clean records back into your PIM/ERP. Upload a sample supplier file for a free catalog audit.
Get a free catalog auditRelated resources
Playbooks
How to Find Functional-Equivalent Products Across Suppliers
When a supplier is out of stock or discontinues a line, finding a true equivalent by spec — not just a similar name — is the difference between a fast substitution and a customer complaint.
Playbooks
How to Group Product Variants Into One Family
A cable gland in five sizes shouldn't be five unrelated catalog entries. Here's how to structure variants so search, filtering, and inventory all make sense.
Glossary
SKU vs MPN vs GTIN: What Each Identifier Does and Why All Three Matter
SKU vs MPN vs GTIN explained: who owns each code, how they differ, and why confusing them breaks matching, dedup, and enrichment.
Guides
Product Compliance Evidence Matrix
A matrix for mapping products and categories to required attributes, evidence files, sources, owners, and review status.