Plumbing & PVF · 18 attributes
Backflow preventer product attributes
Backflow preventer attributes to capture: assembly type and hazard rating, ASSE listing, size, lay length with shutoffs, pressure and temperature range.
Backflow prevention assemblies are bought against a requirement set by the water purveyor or plumbing code, so a vague record is worse than useless. Assembly type (RP, double check, pressure vacuum breaker) determines which hazard it can protect, and the same device appears under a half-dozen abbreviations. The standard listing, such as ASSE 1013 for reduced pressure assemblies, has to be tied to the exact model and size.
Replacement jobs add a physical constraint. A contractor swapping an existing assembly needs the overall lay length with shutoff valves fitted, the end connections and the approved installation orientation. Suppliers often publish lay length without the shutoffs, or give one dimension for a whole series. Orientation approvals are frequently limited to horizontal installs for certain sizes, and that restriction tends to live in a footnote.
Lead-free and standard-material versions, fire-service variants and option suffixes for shutoff type or strainer all multiply the SKU count under one series name. Each variant carries its own part number, weight and approvals. Modeling those options as fields rather than decoding them from the suffix keeps the right approval attached to the right SKU.
The backflow preventers attribute template
18 candidate fields in 5 groups, ordered the way a record gets built: identify the item, capture its specifications, then record fit and the evidence behind any claim. 7 are marked Core: without them the item cannot be identified or filtered. Example values show the expected format only; they do not describe a real SKU.
Identity
Which exact item, variant and pack this record describes.
Check before use: Preserve leading zeros and punctuation, validate against the manufacturer record, and check the GTIN check digit and packaging level before linking.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Manufacturer Part Number manufacturer_part_number | Identifier | Core | BFP-RP-075-LF |
Series & Option Code series_option_code | Identifier | Buyer decision | RP-500 / LF-QT |
Technical specifications
Measured or rated values that must travel with their unit and test conditions.
Check before use: Store the number and unit separately. Convert only when the source unit and test conditions are known.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Nominal Size nominal_size | Controlled list · in | Core | 3/4 in (DN 20) |
Maximum Working Pressure maximum_working_pressure | Number · psi | Core | 175 |
Working Temperature Range working_temperature_range | Text · °F | Core | 33 to 140 °F |
Overall Lay Length overall_lay_length | Number · in | Buyer decision | 10.25 |
Test Cocks (Qty x Size) test_cocks_qty_x_size | Text | Buyer decision | 4 x 1/4 in |
Selection attributes
The type, material and option choices buyers filter and compare on.
Check before use: Map supplier wording to a governed vocabulary only after checking the source text and which variant it applies to.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Assembly Type assembly_type | Controlled list | Core | Reduced Pressure Principle Assembly (RP) |
Body Material body_material | Controlled list | Core | Lead-free cast bronze |
Hazard Level hazard_level | Controlled list | Buyer decision | High hazard (health hazard) |
Shutoff Valve Type shutoff_valve_type | Controlled list | Buyer decision | Quarter-turn ball valves |
Service service | Controlled list | Buyer decision | Potable water |
Fit & compatibility
What the item mounts to, mates with, replaces or works alongside.
Check before use: Keep model and series qualifiers. A similar-looking part is not a verified fit until a source says so.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
End Connection end_connection | Controlled list | Core | FNPT (ASME B1.20.1) |
Approved Installation Orientation approved_installation_orientation | Controlled list | Buyer decision | Horizontal only |
Evidence & compliance
Listings, standards, classifications and origin claims that need a document behind them.
Check before use: Link the manufacturer document or label with its edition or date. Never copy a certification from a neighboring SKU.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
ASSE Standard Listing asse_standard_listing | Controlled list | Channel / evidence | ASSE 1013 |
Third-Party Approvals third_party_approvals | Text | Channel / evidence | NSF/ANSI/CAN 61 and 372; IAPMO; CSA B64.4 |
UL/FM Fire Service Approval ul_fm_fire_service_approval | Text | Channel / evidence | Not listed (potable service model) |
Country of Origin country_of_origin | Controlled list | Channel / evidence | United States |
Normalize supplier values
The same value arrives in many spellings. Map each raw string to one governed value, and keep the raw text beside it so a reviewer can see what the supplier actually wrote.
Assembly Type
RPZRPRPZARPBAReduced Pressure ZoneRed. Press. Principle Normalized to Reduced Pressure Principle Assembly (RP)
End Connection
FNPTFIPFemale NPTF NPTFPTNPT-F Normalized to FNPT
Nominal Size
3/4"3/4 in0.75DN203/4 IN.3/4-inch Normalized to 3/4 in (DN 20)
Often missing from supplier files
These fields are commonly absent from price lists and basic feeds, even though the information usually exists in a datasheet, label or installation manual. Treat an empty value as a request for evidence, not as permission to fill it from a similar model.
- Purveyor / USC Approval Status and Date Checked
- Overall Lay Length Including Shutoff Valves
- Approved Installation Orientation
- Lead-Free Certification Basis (NSF/ANSI/CAN 372)
- Relief Valve Discharge Rate / Air Gap Fitting
Questions the record must answer
Buyers and counter-sales reps choosing backflow preventers ask questions like these. Each one needs a specific field, sourced for the exact variant.
- Is this assembly approved for a high-hazard connection like a boiler feed or chemical line?
- Is this model and size on our water purveyor's approved list right now?
- Will it fit the gap left by the old assembly, including the shutoff valves?
- Can it be installed vertically, or only horizontally?
From supplier file to record
- Resolve identity first. Link the supplier SKU, manufacturer part number and packaging identifiers without merging distinct variants or pack sizes.
- Extract with the source attached. Pull values from rows, tables and datasheets, keeping the raw text, unit and page or row reference.
- Map to your classification. Assign the ETIM, ECLASS, UNSPSC or internal class your company licenses, and keep the supplier's original terms.
- Review, sync and watch. Hold conflicts and safety-related values for a category expert, write approved values to ERP or PIM, and recheck when the supplier sends a new file.
For the full method, see how to build a category attribute template and the category catalog gap audit.
FAQ
Are RP, RPZ, RPZA and RPBA different kinds of backflow preventer?
They are regional and manufacturer names for the same device class, the reduced pressure principle assembly. Normalize them to one controlled value for assembly type and keep the supplier's wording as a search alias so a counter rep typing RPZ still finds the record. Keep the reduced pressure detector assembly (RPDA), used on fire lines, as a separate value because it adds a bypass meter and has its own listing.
If the ASSE listing is stored, is a separate field for purveyor approvals still needed?
Usually yes. An ASSE listing shows the design meets a performance standard. Many water purveyors also require the model to appear on an approved list, often based on field evaluation by the USC Foundation for Cross-Connection Control and Hydraulic Research, and that approval can be limited to certain sizes and orientations and is renewed periodically. Store approval body, scope, and the date the status was last checked, and confirm against the current list before quoting.
Why do two backflow assemblies that look alike have different temperature ratings?
Elastomer compounds, relief valve design and whether the model is intended for hot water all change the rated range, even within one series. Store minimum and maximum working temperature as numeric fields on each SKU instead of inheriting a series value. The lower bound matters too, because most assemblies are rated only down to just above freezing and need protection or a heated enclosure outdoors. Take both values from the manufacturer's specification sheet for that model.
How should lead-free and standard-bronze versions be modeled?
As separate SKUs, each with its own part number, GTIN and evidence record, not as a single product with a material toggle. Store a lead-free status field with its basis, such as NSF/ANSI/CAN 372 certification, and a service field stating whether the version is intended for potable water. In the United States, products used in systems providing drinking water are expected to meet the federal lead-free definition, so rely on the manufacturer's current documentation and local code for any exemption.
Claro
See where your catalog breaks — free
Claro runs this automatically: resolve identity, fill missing attributes, validate updates, and write clean records back into your PIM/ERP. Upload a sample supplier file for a free catalog audit.
Get a free catalog auditRelated resources
Guides
Product Data Management for Plumbing Distribution
Plumbing catalogs mix dozens of manufacturers, regional standards, and compatibility rules that aren't obvious from a part number. Here's what makes this vertical distinct.
Guides
Product Compliance Evidence Matrix
A matrix for mapping products and categories to required attributes, evidence files, sources, owners, and review status.
Guides
How to Match Compliance Documents to the Correct Product and Variant
A practical guide to matching supplier codes, GTINs, MPNs, model names, and document content to the right SKU or variant.
Comparisons
NPT vs BSP vs Metric Threads: Side-by-Side Comparison
NPT vs BSP threads vs metric compared side by side: taper, sealing, sizing, and how to enrich thread attributes cleanly in a product catalog.