Plumbing & PVF · 18 attributes

Commercial faucet product attributes

Commercial faucet attributes to capture: mounting centers, flow rate at a stated pressure, metering cycle volume, activation type and drinking-water listings.

Download CSV template JSON Editorial reference

Commercial faucets are sold into washrooms and kitchens where the fixture, the sink holes and local water-use rules all constrain the choice. The deciding facts are spread across a spec sheet: hole count and centers, spout reach, the aerator or laminar insert that sets flow, and for metering or sensor models the cycle volume and run time. Supplier files often print a flow rate without the test pressure or insert type.

One base model can generate hundreds of orderable part numbers once spout length, handle style, finish, flow insert, cycle setting and power option are combined. When those options are encoded only in a suffix, search and filtering fail and a buyer ends up with a 1.5 gpm kitchen insert on a lavatory that needed 0.5 gpm. Each option belongs in its own field.

Drinking-water and performance certifications also need care. Lead content, contaminant leaching for end-point devices and the plumbing-fitting performance standard are three different claims. Recording each with its standard and certifier, per SKU, keeps a school or hospital submittal from resting on a broad series-level statement that may not cover the part installed.

The commercial faucets attribute template

18 candidate fields in 5 groups, ordered the way a record gets built: identify the item, capture its specifications, then record fit and the evidence behind any claim. 10 are marked Core: without them the item cannot be identified or filtered. Example values show the expected format only; they do not describe a real SKU.

Identity

Which exact item, variant and pack this record describes.

Check before use: Preserve leading zeros and punctuation, validate against the manufacturer record, and check the GTIN check digit and packaging level before linking.

Attribute Type Priority Example format
Manufacturer Part Number (MPN) manufacturer_part_number_mpn Identifier Core CF-4410-CP
GTIN-14 / UPC gtin_14_upc Identifier Core 10614141220042

Technical specifications

Measured or rated values that must travel with their unit and test conditions.

Check before use: Store the number and unit separately. Convert only when the source unit and test conditions are known.

Attribute Type Priority Example format
Spout Reach (center-to-center) spout_reach_center_to_center Number · in Core 4-1/8
Flow Rate at 60 psi flow_rate_at_60_psi Number · gpm Core 0.5
Metering Cycle Time metering_cycle_time Text · s Buyer decision 5-30 s adjustable
Cycle Volume cycle_volume Number · gal/cycle Buyer decision 0.20

Selection attributes

The type, material and option choices buyers filter and compare on.

Check before use: Map supplier wording to a governed vocabulary only after checking the source text and which variant it applies to.

Attribute Type Priority Example format
Faucet Type faucet_type Controlled list Core Metering faucet
Activation Type activation_type Controlled list Core Push-button metering
Finish finish Controlled list Core Polished Chrome
Spout Style spout_style Controlled list Buyer decision Fixed low-profile
Body Material body_material Controlled list Buyer decision Cast brass
Power Source power_source Controlled list Buyer decision None (mechanical metering)

Fit & compatibility

What the item mounts to, mates with, replaces or works alongside.

Check before use: Keep model and series qualifiers. A similar-looking part is not a verified fit until a source says so.

Attribute Type Priority Example format
Mounting Type mounting_type Controlled list Core Deck-mount
Mounting Centers / Hole Configuration mounting_centers_hole_configuration Controlled list · in Core 4 in centerset (3-hole)
Inlet Connection inlet_connection Text Buyer decision 1/2 in NPSM male shank

Evidence & compliance

Listings, standards, classifications and origin claims that need a document behind them.

Check before use: Link the manufacturer document or label with its edition or date. Never copy a certification from a neighboring SKU.

Attribute Type Priority Example format
Country of Origin country_of_origin Controlled list Core United States
Plumbing Fitting Standard plumbing_fitting_standard Controlled list Channel / evidence ASME A112.18.1/CSA B125.1
Drinking Water Certification drinking_water_certification Controlled list Channel / evidence NSF/ANSI/CAN 61 Section 9; NSF/ANSI/CAN 372

Normalize supplier values

The same value arrives in many spellings. Map each raw string to one governed value, and keep the raw text beside it so a reviewer can see what the supplier actually wrote.

Mounting Centers

4"4 inch centerset4in CCCenterset 4102mm4" C-C

Normalized to 4 in centerset

Flow Rate

0.5 GPM.5 gpm @ 60 psi1.9 L/min1.9 LPM0.50.5GPM

Normalized to 0.5 gpm @ 60 psi

Finish

CPPCChromeChrome PlatedPolished ChromeChr

Normalized to Polished Chrome

Often missing from supplier files

These fields are commonly absent from price lists and basic feeds, even though the information usually exists in a datasheet, label or installation manual. Treat an empty value as a request for evidence, not as permission to fill it from a similar model.

  • Aerator / Outlet Type and Supplied Insert Flow Rate
  • Shank Length / Maximum Deck Thickness
  • Rated Operating Pressure and Temperature Range
  • Metering Cycle Time and Cycle Volume
  • Power Source and Backup Mode

Questions the record must answer

Buyers and counter-sales reps choosing commercial faucets ask questions like these. Each one needs a specific field, sourced for the exact variant.

  • Will this fit the three holes on 4-inch centers in our existing lavatory?
  • Does it meet the 0.5 gpm limit for a public lavatory?
  • How long does it run after one push, and can we shorten the cycle?
  • Is it certified for drinking-water use if a sink doubles as a fill station?

From supplier file to record

  1. Resolve identity first. Link the supplier SKU, manufacturer part number and packaging identifiers without merging distinct variants or pack sizes.
  2. Extract with the source attached. Pull values from rows, tables and datasheets, keeping the raw text, unit and page or row reference.
  3. Map to your classification. Assign the ETIM, ECLASS, UNSPSC or internal class your company licenses, and keep the supplier's original terms.
  4. Review, sync and watch. Hold conflicts and safety-related values for a category expert, write approved values to ERP or PIM, and recheck when the supplier sends a new file.

For the full method, see how to build a category attribute template and the category catalog gap audit.

FAQ

Why is gpm not enough to specify a metering faucet?

A metering faucet delivers water in timed bursts, so the amount used per activation depends on the cycle volume and run time as well as the flow rate. Plumbing codes and water-efficiency programs often limit metering faucets by volume per cycle rather than by gpm. Store flow rate as a number with its test pressure, cycle volume in gallons per cycle, the cycle time range in seconds, and whether the cycle is adjustable in the field.

Should the record carry an 'ADA compliant' yes/no flag?

A single flag is risky, because accessibility compliance depends on the installation: mounting height, reach range and clearances, not just the faucet. What the product contributes is its operating characteristics, such as one-hand operation without tight grasping and operating force. Store those features as fields, plus the manufacturer's accessibility statement verbatim with its source document, and let the specifier judge compliance against the applicable accessibility standard.

Which drinking-water certifications belong on a faucet record?

Usually two, stored separately. NSF/ANSI/CAN 372 addresses the lead content of wetted surfaces. NSF/ANSI/CAN 61 Section 9 covers contaminants that leach from end-point devices such as lavatory and kitchen faucets. Performance and marking requirements for the fitting itself fall under ASME A112.18.1/CSA B125.1. Keep each as its own evidence field with the certifier and listing reference, and verify against the certifier's current directory before publishing.

Why does one faucet model turn into hundreds of SKUs?

Each combination of spout length, handle, finish, flow insert, cycle setting, power option and mounting kit is a separate orderable part. Model the family as a parent with variants, and give every option its own controlled field so buyers can filter on flow rate or finish instead of decoding suffix characters. Each variant still needs its own MPN and GTIN, and any certification that is limited to certain configurations should be attached at the variant level.

Claro

See where your catalog breaks — free

Claro runs this automatically: resolve identity, fill missing attributes, validate updates, and write clean records back into your PIM/ERP. Upload a sample supplier file for a free catalog audit.

Get a free catalog audit

Related resources

More Plumbing & PVF templates