Pump, Valve & Process Equipment · 18 attributes

Pressure gauge product attributes

Product data fields for pressure gauges: dial size, pressure range and units, connection size, thread and location, accuracy grade, and wetted materials.

Download CSV template JSON Editorial reference

Pressure gauges are easy to describe loosely and hard to match exactly. A supplier line such as "4 in 0-160 psi 1/4 NPT LM glycerine" packs five attributes into a string, and the abbreviations vary by supplier. Connection location is a common casualty: lower mount and center back mount gauges with identical dials are not interchangeable in a panel or on a pipe tee.

Standards add a layer of translation. North American gauges are typically specified to ASME B40.100 accuracy grades and dial sizes in inches, while European gauges follow EN 837-1 classes and nominal sizes in millimeters. The two systems are close but not identical, and connection threads differ in the same way: NPT, BSPP and BSPT fittings in the same nominal size do not seal against each other.

A buyer replacing a gauge needs the range and scale units, the connection size, thread and position, the dial size, and the wetted material for the process fluid. For demanding service they also need the case fill, the safety pattern, overpressure limits and any hazardous-area or regional registration, all taken from the manufacturer's current data sheet.

The pressure gauges attribute template

18 candidate fields in 5 groups, ordered the way a record gets built: identify the item, capture its specifications, then record fit and the evidence behind any claim. 10 are marked Core: without them the item cannot be identified or filtered. Example values show the expected format only; they do not describe a real SKU.

Identity

Which exact item, variant and pack this record describes.

Check before use: Preserve leading zeros and punctuation, validate against the manufacturer record, and check the GTIN check digit and packaging level before linking.

Attribute Type Priority Example format
Manufacturer Part Number manufacturer_part_number Identifier Core PG-100-316-160-LM
GTIN / UPC gtin_upc Identifier Channel / evidence 00614141000913

Technical specifications

Measured or rated values that must travel with their unit and test conditions.

Check before use: Store the number and unit separately. Convert only when the source unit and test conditions are known.

Attribute Type Priority Example format
Nominal Dial Size nominal_dial_size Controlled list · in Core 4 in [NS 100]
Pressure Range (Scale Range) pressure_range_scale_range Text · psi Core 0 to 160 psi
Accuracy Grade / Class accuracy_grade_class Controlled list Core ASME B40.100 Grade 1A (±1% of span)
Overpressure / Pressure Limitation overpressure_pressure_limitation Text Buyer decision Steady 1.0 × FS; fluctuating 0.9 × FS; short-time 1.3 × FS
Medium Temperature Range medium_temperature_range Text · °C Buyer decision -20 to +100 °C (glycerine filled)
Ingress Protection Rating ingress_protection_rating Controlled list Buyer decision IP65 per IEC/EN 60529

Selection attributes

The type, material and option choices buyers filter and compare on.

Check before use: Map supplier wording to a governed vocabulary only after checking the source text and which variant it applies to.

Attribute Type Priority Example format
Gauge Type gauge_type Controlled list Core Bourdon tube, C-type
Scale Unit scale_unit Controlled list Core psi / bar dual scale
Wetted Parts Material wetted_parts_material Controlled list Core Stainless steel 316L (1.4404)
Case Filling case_filling Controlled list Core Glycerine
Case Material case_material Controlled list Buyer decision Stainless steel 304 (1.4301)
Safety Pattern (EN 837-1) safety_pattern_en_837_1 Controlled list Channel / evidence S3 (solid front, blow-out back)

Fit & compatibility

What the item mounts to, mates with, replaces or works alongside.

Check before use: Keep model and series qualifiers. A similar-looking part is not a verified fit until a source says so.

Attribute Type Priority Example format
Process Connection Size & Thread Standard process_connection_size_thread_standard Controlled list Core 1/4 in NPT male (ASME B1.20.1)
Connection Location connection_location Controlled list Core Lower mount (radial)

Evidence & compliance

Listings, standards, classifications and origin claims that need a document behind them.

Check before use: Link the manufacturer document or label with its edition or date. Never copy a certification from a neighboring SKU.

Attribute Type Priority Example format
Hazardous Area Approval hazardous_area_approval Controlled list Channel / evidence ATEX II 2G Ex h IIC T6...T1 Gb X
Country of Origin country_of_origin Controlled list Channel / evidence Germany

Normalize supplier values

The same value arrives in many spellings. Map each raw string to one governed value, and keep the raw text beside it so a reviewer can see what the supplier actually wrote.

Process Connection Size & Thread Standard

1/4 NPT1/4" MNPT¼ NPT MNPT 1/4 male1/4-18 NPT1/4 in. NPT(M)

Normalized to 1/4 in NPT male (ASME B1.20.1)

Nominal Dial Size

4"100mmNS1004 inØ1004.0 in

Normalized to 4 in [NS 100]

Case Filling

Glycerine FilledGly. FilledGlycerinGlycerin-filledGFLiquid-filled (glycerine)

Normalized to Glycerine

Often missing from supplier files

These fields are commonly absent from price lists and basic feeds, even though the information usually exists in a datasheet, label or installation manual. Treat an empty value as a request for evidence, not as permission to fill it from a similar model.

  • Safety pattern (EN 837-1 S1 / S2 / S3)
  • Canadian Registration Number (CRN)
  • Oxygen service cleaning
  • Overpressure / pressure limitation
  • Restrictor or snubber orifice

Questions the record must answer

Buyers and counter-sales reps choosing pressure gauges ask questions like these. Each one needs a specific field, sourced for the exact variant.

  • Is this gauge bottom connected or back connected, and what thread is it?
  • Will the 316 wetted parts handle our process fluid?
  • Does it read in both psi and bar?
  • Is it registered for use in our province or approved for our hazardous area?

From supplier file to record

  1. Resolve identity first. Link the supplier SKU, manufacturer part number and packaging identifiers without merging distinct variants or pack sizes.
  2. Extract with the source attached. Pull values from rows, tables and datasheets, keeping the raw text, unit and page or row reference.
  3. Map to your classification. Assign the ETIM, ECLASS, UNSPSC or internal class your company licenses, and keep the supplier's original terms.
  4. Review, sync and watch. Hold conflicts and safety-related values for a category expert, write approved values to ERP or PIM, and recheck when the supplier sends a new file.

For the full method, see how to build a category attribute template and the category catalog gap audit.

FAQ

Can a 4 in dial and an NS 100 dial be treated as the same size?

They are nominal equivalents and usually fit the same space, but they are not always dimensionally identical, so a panel cutout or mounting flange should be checked against the manufacturer's drawing. Store dial size as a controlled value that keeps both the inch and the millimeter designation, and keep case diameter and flange dimensions as separate numeric fields when the product is sold for panel mounting.

How do ASME accuracy grades relate to EN 837-1 accuracy classes?

They express accuracy differently. ASME B40.100 grades define permissible error as a percentage of span, and some grades allow a wider error at the ends of the scale than in the middle. EN 837-1 classes express error as a percentage of the scale range. Store the grade or class exactly as the manufacturer declares it, with the standard named, and avoid converting one into the other automatically.

Why should wetted materials be stored separately from the case material?

The case protects the mechanism from the environment, while the wetted parts, such as the Bourdon tube, socket and any seals, are the only parts the process fluid touches. A gauge with a stainless case may still have copper alloy wetted parts. Chemical compatibility depends on the wetted materials, so they need their own controlled field, normalized to recognized material designations.

How do full scale value and overpressure limit differ?

Full scale is the top of the dial range. The overpressure or pressure limitation values state how much steady, fluctuating or short-term pressure the gauge can withstand relative to full scale without losing accuracy or failing. Manufacturers state these differently, so store the range as numbers with units and the pressure limitation as a structured text field copied from the data sheet, with the source linked.

Claro

See where your catalog breaks — free

Claro runs this automatically: resolve identity, fill missing attributes, validate updates, and write clean records back into your PIM/ERP. Upload a sample supplier file for a free catalog audit.

Get a free catalog audit

Related resources

More Pump, Valve & Process Equipment templates