Medical & Dental Supply · 18 attributes
Diagnostic equipment product attributes
Diagnostic equipment attributes for catalog records: device type, measured parameters, patient population, sensor compatibility, UDI-DI and regulatory status.
Diagnostic equipment covers devices as different as patient monitors, blood pressure units, pulse oximeters and thermometers, and the records share one problem: a model name describes a family, not a product. Monitors in particular are sold as configurations, with parameter modules, sensor platforms and connectivity options that change what the device measures and which accessories it accepts. A supplier line that repeats the model name hides those differences.
The details sit in operator manuals, accessory lists and regulatory filings. Patient population, sensor compatibility, electrical classification and applied-part type rarely appear in a price file, and supplier spellings for parameters and populations vary widely. Regulatory status is often written loosely, for example "FDA approved" for a device that was cleared through a 510(k), which a catalog should not repeat.
A buyer needs to know what the device measures, for which patients, what power and connectivity it has, and which sensors and cuffs it works with. Each of those, together with the device identifier and regulatory status, should be a separate field traced to the manufacturer's documentation.
The diagnostic equipment attribute template
18 candidate fields in 5 groups, ordered the way a record gets built: identify the item, capture its specifications, then record fit and the evidence behind any claim. 8 are marked Core: without them the item cannot be identified or filtered. Example values show the expected format only; they do not describe a real SKU.
Identity
Which exact item, variant and pack this record describes.
Check before use: Preserve leading zeros and punctuation, validate against the manufacturer record, and check the GTIN check digit and packaging level before linking.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Manufacturer manufacturer | Text | Core | Manufacturer name as printed on the device label |
Manufacturer Part Number (MPN) manufacturer_part_number_mpn | Identifier | Core | VS-6200-A |
GTIN-14 gtin_14 | Identifier | Core | 00841234601157 |
UDI-DI (GUDID Primary DI) udi_di_gudid_primary_di | Identifier | Channel / evidence | 00841234601157 |
Technical specifications
Measured or rated values that must travel with their unit and test conditions.
Check before use: Store the number and unit separately. Convert only when the source unit and test conditions are known.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Power Source power_source | Text | Core | AC 100–240 V, 50/60 Hz + internal Li-ion (2550 mAh) |
NIBP Measuring Range (adult systolic) nibp_measuring_range_adult_sys | Text · mmHg | Buyer decision | 40–270 |
SpO2 Accuracy (Arms) spo2_accuracy_arms | Number · % | Buyer decision | 2 |
Ingress Protection Rating ingress_protection_rating | Controlled list | Buyer decision | IPX1 |
Selection attributes
The type, material and option choices buyers filter and compare on.
Check before use: Map supplier wording to a governed vocabulary only after checking the source text and which variant it applies to.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Device Type device_type | Controlled list | Core | Multiparameter vital signs monitor |
Measured Parameters measured_parameters | Controlled list | Core | ECG; RESP; SpO2; NIBP; TEMP; CO2 |
Patient Population patient_population | Controlled list | Core | Adult; Pediatric; Neonatal |
ECG Lead Configuration ecg_lead_configuration | Controlled list | Buyer decision | 5-electrode (I, II, III, aVR, aVL, aVF, V) |
Connectivity / Data Output connectivity_data_output | Controlled list | Buyer decision | Wi-Fi 802.11a/b/g/n; HL7; USB |
Fit & compatibility
What the item mounts to, mates with, replaces or works alongside.
Check before use: Keep model and series qualifiers. A similar-looking part is not a verified fit until a source says so.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
SpO2 Sensor Platform spo2_sensor_platform | Controlled list | Buyer decision | OEM-specific sensor family (per manufacturer accessory list) |
Evidence & compliance
Listings, standards, classifications and origin claims that need a document behind them.
Check before use: Link the manufacturer document or label with its edition or date. Never copy a certification from a neighboring SKU.
| Attribute | Type | Priority | Example format |
|---|---|---|---|
Country of Origin country_of_origin | Controlled list | Core | China |
Regulatory Status regulatory_status | Controlled list | Channel / evidence | Class II, 510(k) cleared, Rx only |
Electrical Class & Applied Part Type electrical_class_applied_part_type | Controlled list | Channel / evidence | Class I; Type CF, defibrillation-proof |
Standards Conformance standards_conformance | Text | Channel / evidence | IEC 60601-1; IEC 60601-1-2; IEC 80601-2-30; ISO 80601-2-61 |
Normalize supplier values
The same value arrives in many spellings. Map each raw string to one governed value, and keep the raw text beside it so a reviewer can see what the supplier actually wrote.
Patient Population
ADU/PED/NEOA/P/NAdult, Pediatric, NeonateAdult/Paed/NeoAdult; Paediatric; NeonatalAdult-Pediatric-Neonatal Normalized to Adult; Pediatric; Neonatal
NIBP Pressure Unit
mmHgmm HgmmhgMMHGmm-Hgmillimeters of mercury Normalized to mmHg
Measured Parameter (oxygen saturation)
SpO2SPO2Sp02SpO₂Pulse oxOxygen saturation Normalized to SpO2
Often missing from supplier files
These fields are commonly absent from price lists and basic feeds, even though the information usually exists in a datasheet, label or installation manual. Treat an empty value as a request for evidence, not as permission to fill it from a similar model.
- Patient Population (adult, pediatric, neonatal)
- SpO2 Sensor Platform / Probe Connector
- Applied Part Type and Defibrillation-Proof Rating
- MR Safety Status
- Regulatory Status (class, clearance pathway, Rx/OTC)
Questions the record must answer
Buyers and counter-sales reps choosing diagnostic equipment ask questions like these. Each one needs a specific field, sourced for the exact variant.
- Will our existing SpO2 sensors and blood pressure cuffs work with this monitor?
- Is this monitor indicated for neonatal patients?
- Can it send vitals to our electronic health record over Wi-Fi?
- How long does it run on battery during patient transport?
From supplier file to record
- Resolve identity first. Link the supplier SKU, manufacturer part number and packaging identifiers without merging distinct variants or pack sizes.
- Extract with the source attached. Pull values from rows, tables and datasheets, keeping the raw text, unit and page or row reference.
- Map to your classification. Assign the ETIM, ECLASS, UNSPSC or internal class your company licenses, and keep the supplier's original terms.
- Review, sync and watch. Hold conflicts and safety-related values for a category expert, write approved values to ERP or PIM, and recheck when the supplier sends a new file.
For the full method, see how to build a category attribute template and the category catalog gap audit.
FAQ
Is the UDI-DI the same number as the GTIN?
Often, but not always. When GS1 is the issuing agency, the device identifier is a GTIN, so the values match for that package level. Devices can also use other FDA-accredited issuing agencies, and each package level (each, box, case) has its own device identifier. Store the UDI-DI as its own field per package level, record the issuing agency, and check it against the device's GUDID listing rather than copying the retail GTIN from a price file.
Which standards apply to electrical diagnostic devices?
Medical electrical equipment is commonly evaluated against IEC 60601-1 for general safety and IEC 60601-1-2 for electromagnetic compatibility, plus particular standards for specific functions, such as those covering automated blood pressure measurement or pulse oximetry. Which standards apply depends on the device, so store only the standards and editions the manufacturer declares for that model, as structured evidence. The regulatory status in each market should come from the manufacturer's current documentation or the regulator's database.
Why give patient population its own field?
Because it drives both device selection and accessory compatibility. A monitor that supports neonatal patients needs different cuffs and sensors, and some measurement ranges differ by population. Store patient population as a multi-value controlled field (adult, pediatric, neonatal) rather than free text, so buyers can filter on it and accessory records can be linked to the populations they serve. Take the values from the manufacturer's indications for use.
How should a monitor family with many configurations be modeled?
Use a parent record for the model family and a child record for each orderable configuration, with its own part number, device identifier and measured-parameter list. Attributes that genuinely vary, such as parameters, sensor platform, connectivity and battery, belong on the child. Shared documents like the operator manual can attach to the parent. This keeps search accurate and prevents a buyer from assuming that every configuration measures CO2 because one of them does.
Claro
See where your catalog breaks — free
Claro runs this automatically: resolve identity, fill missing attributes, validate updates, and write clean records back into your PIM/ERP. Upload a sample supplier file for a free catalog audit.
Get a free catalog auditRelated resources
Guides
HS Codes for Pharmaceuticals and Medical Devices
How to manage HS and tariff codes for pharmaceuticals and medical devices, where customs classification overlaps with FDA, CBP, and product regulatory data.
Guides
How to Match Compliance Documents to the Correct Product and Variant
A practical guide to matching supplier codes, GTINs, MPNs, model names, and document content to the right SKU or variant.
Comparisons
GTIN vs MPN vs SKU: Which Product Identifier Does What?
GTIN, MPN, and SKU are not interchangeable. Learn which identifier to use for catalog matching, supplier feeds, and marketplace listings.
Free Tools
GTIN / EAN / UPC Validator
Free GTIN validator: paste or upload GTIN-8, UPC-A, EAN-13, or GTIN-14 codes to verify length, check digit, and format. Runs in your browser.